Significant proportion of the total energy expenditure for the heat treatment of raw materials are heat losses through the shell of rotary furnace. Currently, the waste heat is not used in any way and escapes into the environment. Controlled cooling system for rotary furnace shell (CCSRF) is a new solution integrated into the technological process aimed at reducing the heat loss of the furnace shell. Based on simulations and experiments carried out was demonstrated a significant effect of controlled cooling shell to the rotary furnace work. The proposed solution is cost-effective and operationally undemanding.Downloads
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.