COUPLED ELECTROMAGNETIC-THERMAL SIMULATION OF A POWER TRANSFORMER BY 3D FEM
DOI:
https://doi.org/10.14311/AP.2020.60.0400Keywords:
power transformer, thermal simulation, finite element method, hot spot, CFDAbstract
Power transformers are the most common equipment in an electric power system, which has been manufactured in the last decade. However, overheating can damage them, considerably reducing their operation lives, which may cause economic losses to the power utilities. The motivation of this paper is to investigate the time and power overload limits that a power transformer can be subjected to and how it will impact its temperature. Investments in the grid can be delayed if a transformer can support some overload during some momentary load demand increase. In this context, this paper presents a study of a 30/40MVA power transformer by 3D finite element method (FEM) for coupled thermal-electromagnetic simulations to investigate its thermal behaviour when it is submitted to its nominal load at a steady-state operation and a variable load during a period of one day. The simulations were performed with the commercial software packages Flux 3D and AcuSolve, for electromagnetic and thermal modelling, respectively. The modelled equipment was based on a power transformer installed in the Light Serviços de Eletricidade S.A, the utility that supplies electrical energy to the city of Rio de Janeiro, in Brazil. Since the literature doesn’t present many works simulating coupled thermal-electromagnetic power transformers in 3D-FEM, this paper has the goal to bring new contributions to this field. Three study cases were modelled, and some simplifications in transformer’s geometry were made in some of them to reduce the computation time usually required for such a simulation. The obtained results are presented and compared with the measured values for the temperature in the hot spot of the transformer and in the top of the oil, to investigate the impact of these simplifications in the calculated results.
Downloads
References
Khator, S.K., Leung, L.C.: Power distribution planning: a review of models and issues. IEEE Trans. on Power Systems, 12, 1997, p. 1151-1159, DOI: 10.1109/59.630455.
Swift, G.W. et al.: Adaptive transformer thermal overload protection. IEEE Trans. on Power Delivery, 16, 2001, p. 516-521, DOI: 10.1109/61.956730.
Jardini, J. A. et al. Power transformer temperature evaluation for overloading conditions. IEEE Trans. on Power Delivery, 20, 2005, p. 179-184, DOI: 10.1109/TPWRD.2004.835433
Christina, A.J. et al.: “Causes of transformer failures and diagnostic methods–A review. Renewable and Sustainable Energy Reviews, 82, 2018, p. 1442-1456, DOI: 10.1016/j.rser.2017.05.165.
Sitar, R., Sulc, I., Janic, Z.: Prediction of local temperature rise in power transformer tank by FEM. Procedia Engineering, 202, 2017, p.231-239, DOI: 10.1016/j.proeng.2017.09.710.
Chereches, N. et. al.: Numerical Study of Cooling Solutions Inside a Power Transformer. Energy Procedia, 112, 2017, p. 314-321, DOI: 10.1016/j.egypro.2017.03.1103.
Torriano, F. et al.: Numerical and experimental thermofluid investigation of different disc-type power transformer winding arrangements. Int. J. of Heat and Fluid Flow, 69, 2018, p. 62-72, DOI: 10.1016/j.ijheatfluidflow.2017.11.007.
Rodriguez, G.R. et. al.: “Numerical and experimental thermo-fluid dynamic analysis of a power transformer working in ONAN mode. Applied Thermal Engineering, 112, 2017, p. 1271-1280, DOI: 10.1016/j.applthermaleng.2016.08.171.
Córdoba, P.A., Dari, E., Silin, N.: A 3D numerical model of an ONAN distribution transformer. Applied Thermal Engineering, 148, 2019, p.897-906, DOI: 10.1016/j.applthermaleng.2018.11.098.
Tsili, M.A. et. al.: Power transformer thermal analysis by using an advanced coupled 3D heat transfer and fluid flow FEM model. Int. J. of Thermal Sciences, 53, 2012, p.188-201, DOI: 10.1016/j.ijthermalsci.2011.10.010.
Bouissou, S. et al.: Numerical simulation of a power transformer using 3D finite element method coupled to circuit equation. IEEE Trans. on Magnetics, 30, p. 3224-3227, DOI: 10.1109/20.312624.
Susnjic, L., Haznadar, Z., Valkovic, Z.: 3D finite-element determination of stray losses in power transformer. Elec. Power Systems Research, 78, 2008, p.1814-1818, DOI: 10.1016/j.epsr.2008.03.009.
Ahmad, A. et al.: Short Circuit Stress Analysis Using FEM in Power Transformer on H-V Winding Displaced Vertically & Horizontally. Alexandria Eng. Journal, 57, 2018, p.147-157, DOI: 10.1016/j.aej.2016.10.006.
Ahn, H. et al.: Experimental Verification and Finite Element Analysis of Short-Circuit Electromagnetic Force for Dry-Type Transformer. IEEE Trans. on Magnetics, 48, 2012, p. 819-822, DOI: 10.1109/TMAG.2011.2174212
Jimenez-Mondragon, V.M. et al.: Quasi-3-D Finite-Element Modeling of a Power Transformer. IEEE Trans. on Magnetics, 53, 2017, p. 1-4, DOI: 10.1109/TMAG.2017.2659662.
Liao, C. et. al.,: 3-D Coupled Electromagnetic-Fluid-Thermal Analysis of Oil-Immersed Triangular Wound Core Transformer. IEEE Trans. on Magnetics, 50, 2014, p. 1-4, DOI: 10.1109/TMAG.2014.2330953.
Preis, K. et al.: Thermal-electromagnetic coupling in the finite-element simulation of power transformers. IEEE Trans. on Magnetics, 42, 2006, p. 999-1002, DOI: 10.1109/TMAG.2006.871439.
ALTAIR: AcuSolveTM – Finite Element tool for Computational Fluid Dynamics simulation. https://altairhyperworks.com/product/AcuSolve.
Jiao, Y.: CFD Study on the Thermal Performance of Transformer Disc Windings Without Oil Guides. Master of Science Thesis - KTH School of Industrial Engineering and Management, Stockholm, 2012.
Henriques, H.O. et al.: Thermodynamic Models and Three-Dimensional Analysis for Determination of Load Limits Transformers. IEEE Latin America Trans., 11, 2013, p. 1225 - 1229, DOI: 10.1109/TLA.2013.6684397.
Kassi, K.S. et al.: Analysis of Aged Oil on the Cooling of Power Transformers from Computational Fluid Dynamics and Experimental Measurements. J. of Applied Fluid Mechanics, 9, 2016, p. 235 - 243, 2016.
Radakovic, Z.R., Sorgic, M.S.: Basics of Detailed Thermal-Hydraulic Model for Thermal Design of Oil Power Transformers. IEEE Trans. on Power Delivery, 25, 2010, p.790-802, DOI: 10.1109/TPWRD.2009.2033076.
Downloads
Published
Issue
Section
License
Copyright (c) 2020 Henrique Oliveira Henriques, Carlos Eduardo Vizeu, Paulo Cesar Souza, Mauricio Caldora Costa, Guilherme Gonçalves Sotelo, Jonaylton Moura Sousa, Marcio Zamboti Fortes, Vitor Hugo Ferreira

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
4. ddd